Special Building Painting Material Highway/Bridge Anti Rust Paint
The F-102 bridge special paint can be matched with epoxy zinc-rich primer, epoxy anti-rust primer, epoxy zinc yellow primer, and can be used for heavy industry corrosion protection in aviation and seaside steel structures.
Construction reference:
1. The two components are used in proportion according to the requirements, how much is used, how much is used, and the finished paint should be used up within 6h to avoid waste caused by gelation.
2. The surface of the object to be coated must be clean, free of acid, alkali and moisture, and dry and smooth.
3. In order to fully cross-link and cure the two components, it can be cured for 10 minutes at room temperature after painting, and then sprayed. If the viscosity is too large, it can be diluted to a construction viscosity with a special thinner.
4. Because the second component easily reacts with water, acid, etc., a special thinner must be used during use. Do not contact with water, gasoline or alcohol. The packaging of the second component after painting should be tightly sealed to avoid glue. Metamorphosis causes waste.
Technical Parameters:
Surface Finish |
Smooth and flat |
Fineness,um |
≤30-40 |
Solid Content |
45±2 % |
Flexibility,mm |
≤1 |
Impact Strength |
50 kg/cm2 |
Adhesion |
≤2 |
Drying Time |
Surface |
2h |
Solid |
24h |
Gasoline Resistance (5h) |
The paint film is not sticky or soft |
Distilled water resistance (72h) |
No significant change |
Salt spray resistance (72h) |
No significant change |
ALL THE PICTURES BELOW ARE REAL CASES FROM OUR CUSTOMERS: